Senior Operation Engineer
- MaintenantConception / Génie civil / Génie industriel 1. Safe Start and Shutdown for the unit.
2. DCS Unit Operation Processes.
3. Boiler Operation Processes.
4. Auxiliary Unit Operation Processes including Feed water Pumps, both turbine and electrical.
o Participate in all power steam unit tests (Run back loads – Run down loads– Max capacity rate etc…)
o Responsible for Preparing Safety Permits, Work orders, Work Access Orders for the whole unit.
• Field process Engineer responsible for preparing all system locally such as:
• Main Turbine and its auxiliary system- (SIEMENS).
o Turbine DCS operation and safe startup & shut down & all its auxiliaries (seal oil, lube & control oil, seal steam, vacuum pumps charging generator hydrogen).
o Supervise Start-up, Normal and Shutdown Operation for steam turbine vacuum breaker, saving margin & its tolerance stress
• Main Boiler and its auxiliary system- (BABCOCK)
o Boiler DCS operation and safe startup & shut down (gas & mazout firing) all its axillaries (air heater, forced fans, calibration for air to fuel ratio, reboiling system, soot blower system)
o Supervise Start-up, Normal and Shutdown Operation For the whole unit utilities (condensate water system, Service water system, Circulating water system, steam turbine pump, axial pumps, regeneration heaters, aux header & Aux boiler Compressed Air System
• Desalination Plant - (Hitachi):
o Responsible on safe operation & Maintenance for Multi Stage Flash chamber desalination MSF (20 chambers, 5000 t/day capacity)
o plant and its auxiliaries (Including: Steam Brine Heater System, Condensate Return System, Brine Recirculating system, Blow Down system, Distillate Intake system, Ejectors Evacuation system & Acid Cleaning system).